针对漆包机废气净化处理我们采用低温催化燃烧法,低温催化燃烧处理方式是借助催化剂的催化作用对尾气中有机物进行低温、高效、节能环保型的处理,从而实现达标排放的目的。催化燃烧反应是典型的气—固相催化反应,其实质是在一定温度下,将吸附于催化剂表面的有机物(VOCs)及来自空气中的氧发生催化氧化反应,彻底氧化成无害的CO2 和H2 O,并释放反应热的过程。借助催化剂可大幅降低有机物的起燃温度,进行无焰燃烧,减少预热能耗及NOx的生成。

We adopt the low temperature catalytic combustion method to purify the exhaust gas of the enameled machine. Catalytic combustion at a low temperature is used to treat the organic matter in the exhaust at low temperature, high efficiency, energy saving and environmental protection by the catalysis of catalyst, so as to achieve the goal of emission standards. Catalytic combustion is a typical gas-solid catalytic reaction. Catalytic combustion is a typical gas-solid catalytic reaction. Its essence is at a definite temperature, The process of catalytic oxidation of organic compounds (VOCS) adsorbed on the catalyst surface and oxygen from the air to harmless CO2 and H2O, and the release of reaction heat. With the help of a catalyst, the starting temperature of organic matter can be greatly reduced, flameless combustion can be carried out, and the preheating energy consumption and the formation of NOX can be reduced. 

注意事项
1.安装环保设备时,一定要保证各连接口和管道的密封性,并做好保温措施(包保温棉);避免排废温度过低;避免热量损失造成电热管持续加热(耗能)且影响了催化效果,和气体的无组织排放造成的污染。
2.催化块为易耗品,正常生产的情况下可以使用1-2年,更换催化块时一定要保证内部的密封性,催化块与内胆间隙处,需填充实保温棉,不能有漏风,否则易导致催化失效。
3.使用过程中当温度显示不正常时,可能热电偶,加热管损坏,催化块中毒或密封不好,请定期查验。

1. Installation of environmental protection equipment, it is necessary to ensure the sealing of the junctions and pipelines, and do a good job of insulation measures (covering heating preservation cotton); Avoid low exhaust temperature; avoid heat loss caused by continuous heating (energy consumption) and impact on catalytic effect, and other pollution
caused by inorganic emissions.
2. Catalytic mats are consumable, under normal production conditions can be used for 1-2 years. When replacing the catalytic met, must guarantee the inner sealing. The gap between the catalytic block and the inner tank should be filled with insulation cotton, which cannot leak air. Otherwise, it will easily lead to catalytic failure.
3. When the temperature is abnormal, the thermocouple, heating pipe may be damaged, the catalyst mats poisoning or the seal is not good.Please check regularly.